Model No. | Maximum Material | Maximum Material | A Inlet Port | Static Outlet | Minimum Inlet | Displacement |
GBT-D15/30 | 30 Pa to 2500 psig (2) | 9,000 psig | 1/4" NPT | 60 Pa +2 Ps | 100 psi (7 bar) | 7.05 |
620 bar | 1/4" NPT | |||||
GBT-D15/75 | 7 Pa to 5000 psig (2) | 25,000 psig | 1/4” NPT | 150 Pa + 5 Ps | 100 psig (7 bar) | 7.05 |
1,725 bar | 9/16"-18 (1) | |||||
GBT-D30/75 | 40 Pa to 3600 psig (2) | 25,000 psig | 1/4” NPT | 150 Pa + 2.5 Ps | 100 psig (7 bar) | 3.1 |
1,725 bar bar | 9/16"-18 (1) |
(1) Coned and threaded high pressure connection for 1/4" O.D. tubing.
(2) Limit maximum gas supply pressure by formula Ps max = factor * Pa to avoid interstage stall
(for example, for gas booster model GBT-15/30 the formula is: Ps max = 15*Pa).
M014 - Counter Port: This option provides a 5/8-18-UNF thread port on the air motor section of the pump for installing a mechanical cycle counter. |
M402 - Remote Pilot: This option provides a 1/8'' NPT female port for remotely controlling the start/stop of the pump by connecting an external air signal to actuate the air cycling valve. |